D.L.S. is expanding their airborne equipment explosive atmosphere testing capabilities. This test is implemented to demonstrate equipment’s capability to operate in a flammable environment without causing an explosion, or to show that the design is able to prevent the explosion spreading outside of the enclosure of the equipment.
Method 511 (including 511.5 and 511.7) consist of the following test procedures:
- Procedure I – Explosive Atmosphere Safety and Ignition Testing
- Procedure II – Explosion Containment Testing
D.L.S. provides support for the entire MIL-STD-810 environmental suite of tests up to the current revision level of H.
The tests are often performed in addition to EMI related tests.
Click here to learn about RTCA DO-160 Explosive Atmosphere testing.