Electromagnetic Compatibility
Electrical Power Disturbance
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand, without disruption of normal
operation or loss of data:
a. Surges of 30% dip @10 ms;
b. Surges of 60% dip @100 ms & 1 sec
c. Surges of >95% interrupt @5 sec;
d. Surges of +15% line variations of nominal
line voltage; and
e. Electric power increases of 7.5% and
reductions of 12.5% of nominal specified power supply for a period
of up to four hours at each power level.
Electrical Fast Transient
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand, without disruption of normal
operation or loss of data, electrical fast transients of:
a. 2 kV AC & DC external power lines;
b. +1 kV all external wires >3m no control;
and
c. +2 kV all external wires control.
Lightning Surge
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand, without disruption of normal
operation or loss of data, surges of:
a. +2 kV AC line to line;
b. +2 kV AC line to earth;
c. +.5 kV DC line to line >10m;
d. +.5 kV DC line to earth >10m; and
e. +1 kV I/O signal/control >30m.
Electrostatic Disruption
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand ±15 kV air discharge
and ±8 kV contact discharge without damage or loss of data. The
equipment may reset or have momentary interruption so long as normal operation
is resumed without human intervention or loss of data. Loss of data means
votes that have been completed and confirmed to the voter.
Electromagnetic Radiation
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall comply with the Rules and Regulations of the Federal
Communications Commission, Part 15, Class B requirements for both radiated
and conducted emissions.
Electromagnetic Susceptibility
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand an electromagnetic field of
10 V/m modulated by a 1 kHz 80% AM modulation over the frequency range
of 80 MHz to 1000 MHz, without disruption of normal operation or loss
of data.
Conducted RF Immunity
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand, without disruption of normal
operation or loss of data, conducted RF energy of:
a. 10V AC & DC power; and
b. 10V, 20 signal/control >3m.
Magnetic Fields Immunity
Vote scanning and counting equipment for paper-based systems, and all
DRE equipment, shall be able to withstand, without disruption of normal
operation or loss of data, AC magnetic fields of 30 A/m at 60 Hz.
Equipment Verification
Electromagnetic Compatibility
Electrical Power Disturbance
The test for power disturbance disruption shall be conducted in compliance
with the test specified in IEC 61000-4-11 (1994-06).
Electromagnetic Radiation
The test for electromagnetic radiation shall be conducted in compliance
with the FCC Part 15 Class B requirements by testing per ANSI C63.4.
Electrostatic Disruption
The test for electrostatic disruption shall be conducted in compliance
with the test specified in IEC 61000-4-2 (1995-01).
Electromagnetic Susceptibility
The test for electromagnetic susceptibility shall be conducted in compliance
with the test specified in IEC 61000-4-3 (1996).
Electrical Fast Transient
The test for electrical fast transient protection shall be conducted in
compliance with the test specified in IEC 61000-4-4 (1995-01).
Lightning Surge
The test for lightning surge protection shall be conducted in compliance
with the test specified in IEC 61000-4-5 (1995-02).
Conducted RF Immunity
The test for conducted RF immunity shall be conducted in compliance with
the test specified in IEC 61000-4-6 (1996-04).
Magnetic Fields Immunity
The test for AC magnetic fields RF immunity shall be conducted in compliance
with the test specified in IEC 61000-4-8 (1993-06).
|